For full functionality of this site it is necessary to enable JavaScript.

Hanna HI83308-02 光度计

Wavelength Accuracy: ±1 nm
Light Source: 4 LEDs with 420 nm, 466 nm, 525 nm and 610 nm narrow band interference filters
Spectral bandwidth: 8 nm
Input Channels : 1 pH electrode input and 3 photometer wavelengths
pH Electrode: digital pH electrode (not included)
Logging Type: log on demand with user name and sample ID optional input
Logging Memory: 1000 readings
Connectivity: USB-A host for flash drive; micro-USB-B for power and computer connectivity
GLP: calibration data for connected pH electrode
Display: 128 x 64 pixel LCD with backlight
Battery Type / Life: 3.7 VDC Li-polymer rechargeable battery / >500 photometric measurements or 50 hours of continuous pH measurement
Power Supply: 5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included)
Environment: 0 to 50.0 oC (32 to 122.0 oF); 0 to 95% RH, non-condensing
Dimensions: 206 x 177 x 97 mm (8.1 x 7.0 x 3.8")
Weight : 1.0 kg (2.2 lbs.)
Photometer/Colorimeter Light Detector: silicon photodetector
Cuvette Type : round, 24.6 mm
Number of Methods : 128 max.
Ordering Information: HI83308 is supplied with sample cuvettes and caps (4 ea.), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual.

Details

Manual

Parameter Range Resolution Accuracy (at 25 °C) Method Wavelength Reagent Code
Absorbance 0.000 to 4.000 Abs 0.001 Abs +/-0.003Abs @ 1.000 Abs      
Ammonia, Low Range 0.00 to 3.00 mg/L (as NH3 -N) 0.01 mg/L ±0.04 mg/L ±4% of reading Adaptation of the ASTM Manual of Water and Environmental Technology, D1426 Nessler method. 420 nm HI93700-01
Ammonia, Medium Range  0.00 to10.00 mg/L (as NH3 -N) 0.01 mg/L ±0.05 mg/L ±5% of reading Adaptation of the ASTM Manual of Water and Environmental Technology, D1426, Nessler method 420 nm HI93715-01
Ammonia, High Range  0.0 to 100.0 mg/L (as NH3 -N) 0.1 mg/L ±0.5 mg/L ±5% of reading Adaptation of the ASTM Manual of Water and Environmental Technology, D1426, Nessler method 420 nm HI93733-01
Chlorine, Free  0.00 to 5.00 mg/L (as Cl2 )  0.01 mg/L  ±0.03 mg/L ±3% of reading  Adaptation of the EPA DPD method 330.5 525 nm  HI93701-01
Chlorine, Total  0.00 to 5.00 mg/L (as Cl2 )  0.01 mg/L  ±0.03 mg/L ±3% of reading  Adaptation of the EPA DPD method 330.5  525 nm HI93711-01
Copper, Low Range  0.000 to 1.500 mg/L (as Cu)  0.001 mg/L  ±0.010 mg/L ±5% of reading  Adaptation of the EPA method 575 nm  HI95747-01
Copper, High Range  0.00 to 5.00 mg/L (as Cu)  0.01 mg/L  ±0.02 mg/L ±4% of reading  Adaptation of the EPA method  575 nm HI93702-01
Fluoride, Low Range  0.00 to 2.00 mg/L (as F)  0.01 mg/L  ±0.03 mg/L ±3% of reading  Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, SPADNS method 575 nm  HI93729-01
Iron, Low Range  0.000 to 1.600 mg/L (as Fe)  0.001 mg/L  ±0.010 mg/L ±8% of reading  Adaptation of the TPTZ Method  575 nm HI93746-01
Iron, High Range  0.00 to 5.00 mg/L (as Fe)  0.01 mg/L  ±0.04 mg/L ±2% of reading  Adaptation of the EPA Phenanthroline method 315B, for natural and treated waters  525 nm HI93721-01
Manganese, Low Range  0 to 300 µg/L (as Mn)  1 µg/L  ±10 µg/L ±3% of reading  Adaptation of the PAN Method  575 nm HI93748-01
Manganese, High Range  0.0 to 20.0 mg/L (as Mn)  0.1 mg/L  ±0.2 mg/L ±3% of reading  Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Periodate method 525 nm  HI93709-01
Molybdenum  0.0 to 40.0 mg/L (as Mo6+)  0.1 mg/L  ±0.3 mg/L ±5% of reading  Adaptation of the mercaptoacetic acid method  420 nm HI93730-01
Nickel, Low Range  0.000 to 1.000 mg/L (as Ni)  0.001 mg/L  ±0.010 mg/L ±7% of reading  Adaptation of the PAN method  575 nm HI93740-01
Nickel, High Range  0.00 to 7.00 g/L (as Ni)  0.01 g/L  ±0.07g/L ±4% of reading  Adaptation of the photometric method  575 nm HI93726-01
Nitrate  0.0 to 30.0 mg/L (as NO3 - N)  0.1 mg/L  ±0.5 mg/L ±10% of reading  Adaptation of the cadmium reduction method 525 nm  HI93728-01
Oxygen, Dissolved  0.0 to 10.0 mg/L (as O2 )  0.1 mg/L  ±0.4 mg/L ±3% of reading  Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Azide modified Winkler method  420 nm HI93732-01
pH  6.5 to 8.5 pH  0.1 pH  ±0.1 pH  Adaptation of the Phenol Red method  525 nm HI93710-01
Phosphate, Low Range  0.00 to 2.50 mg/L (as PO4 3-)  0.01 mg/L  ±0.04 mg/L ±4% of reading  Adaptation of the Ascorbic Acid method  610 nm HI93713-01
Phosphate, High Range  0.0 to 30.0 mg/L (as PO4 3-)  0.1 mg/L  ±1.0 mg/L ±4% of reading  Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Amino Acid method  525 nm HI93717-01
Silica, Low Range  0.00 to 2.00 mg/L (as SiO2 )  0.01 mg/L  ±0.03 mg/L ±3% of reading  Adaptation of the ASTM Manual of Water and Environmental Technology, D859, Heteropoly Molybdenum Blue method  610 nm HI93705-01
Silver  0.000 to 1.000 mg/L (as Ag)  0.001 mg/L  ±0.020 mg/L ±5% of reading  Adaptation of the PAN method  575 nm HI93737-01
Zinc  0.00 to 3.00 mg/L (as Zn)  0.01 mg/L  ±0.03 mg/L ±3% of reading  Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, Zincon method  575 nm HI93731-01
  • 质量承诺
  • 正品保修
  • 送货到家
  • 交易简单化

注册收新闻 - 获得优惠活动的机会