For full functionality of this site it is necessary to enable JavaScript.

GFUVE FU2200 RS485 端口三相停止数字功率计

  • 制造商:GFUVE
    Model: FU2200
    来源: China
    保障: 12 Month
    • 报价要求 Request a Quotation
  • 联系
    • 加入购物车
    • 立即购买
  • 价格合理详情请致电

    热线:   (+84) 966520220

    电话:  +84 (24) 62923267


      

Power supply (AC/DC): AC85-265V / DC85-330V, DC18-90V (optional)

Power consumption: <4VA

Measurement parameters: Voltage (Ph-N); Voltage (Ph-Ph); Current; Frequency; PF; Active Power(W); Reactive Power(Q) ; Apparent Power(S), 3rd-19th harmonics

Harmonics:

        Total harmonics ratio of phase-voltage

        Total harmonics ratio of current

        3rd-19th harmonics ratio of Phase-voltage (RS485 output)

        3rd-19th harmonics ration of current (RS485 output)

Maximum value: 

        Max. value for voltage/current

        Max. value for active power

        Max. value for reactive power

        Max. value for apparent power

Computation: 

        Forward active power energy

        Reverse active power energy

        Forward active power energy

        Reverse reactive power energy

Measuring range: 30-600V, 0-6A, 45-65Hz, -1 ~ 0 ~ 1

Measuring accuracy:

        Frequency: 0.1%

        Electric energy: 0.5%, 1.0%

        Voltage: 0.2%±0.1V

        Current: 0.2%±0.001A

        Power: 0.5% ±0.4W

        Power factor: 0.5% ±0.001

Display: Wide screen angle; Light blue back-lit LCD display; 5 display figures; 6 operation keys.

Communication: RS-485 interface port support, 32 (128) Networking, ModBus-RTU communication protocol

Programmable: 

        Measuring system: 3P4W/3P3W etc.

        Transformation ratio : PT,CT.

        Communication:

        Address: 1-247; Baud: 1200-19200; Parity bit: N/E/O

        Energy: reset

Energy pulse (expansion): FM-E2 provides active & reactive energy pulse output. 6 pulse parameters can be choose. Range: 0.1-10000kWh/kvarh; Dry contact output (1AX100V).

Data collection (expansion): Each FM-K2 module can collect 2-ways dry contact counting

Control (expansion module): Each FM-K2 provides 2 relay contact outputs, which can be controlled by communication or the measured parameters.

Analog output (expansion module): Each FM-A20 module provides 2 ways of DC 4-20mA outputs, the function-relations can be set according to the measured parameters.

Connection mode 3P4W, 3P4W BAL, 3P3W, 3P3W BAL, 1P2W, 1P3W

Mechanical parameters 

Dimensions (mm)

        Mounting panel: 96x96

        Thickness: 20

        Depth: 60 (without expansion module)

        80 (without expansion module)

Mounting: Panel mounting

Trepanning: 92x92mm

Environmental conditions 

Temperature: -25 to +50°C

Humidity: 20%-95%RH, Without condensation